Gas water heater safety precautions
CO poisoning prevention: The gas water heater must be installed outside the bathroom, and the exhaust pipe must be installed to ensure the smooth emission of smoke. Users who use artificial gas must regularly (every 3 months or half a year) entrust professional cleaning of the burner.
Gas leakage prevention: Often use soapy water to check whether each gas joint, gas pipeline or hose leaks. Once the hose is found to have cracks, it must be replaced immediately. In case of gas leakage, it is necessary to close the gas valve immediately, open the doors and Windows for ventilation, and disable the telephone and electrical appliances. Users using liquefied petroleum gas are strictly prohibited from placing gas cylinders upside down or sideways. In addition, pay attention to timely replacement of products that exceed the service life.
Anti-leakage: The power supply must have a reliable ground wire, and check the leakage protection switch regularly (weekly) to ensure its normal operation.
Anti-freezing water tank cracking: Gas water heaters in the north must be installed with anti-freezing valves or anti-backwind devices. When the outdoor temperature is lower than 0 ° C, anti-freezing operations must be carried out according to the requirements of the operation manual or the requirements of the anti-freezing warning sticker on the fuselage.